Comprehensive Metal Drywall Construction

Modern wall systems combine multiple components that work together to create structures that are strong, energy-efficient, sound-attenuating, and fire-resistant. This guide provides detailed information on the essential elements of contemporary wall construction with a focus on commercial and high-performance applications.

1. Metal Framing Systems

Metal framing forms the structural backbone of modern wall assemblies, providing superior strength, precision, and fire performance compared to traditional wood framing.

Types of Metal Framing

Structural Steel Studs: Heavy-gauge (12-20 gauge) load-bearing studs designed for exterior walls and structural applications

Non-Structural Steel Studs: Lighter gauge (20-25 gauge) used for interior partitions and non-load-bearing walls

EQ (Equivalent) Studs: Engineered studs with embossed patterns that increase strength while using less material

Shaft Wall Studs: Specialized C-H or I-shaped studs designed for elevator shafts and stairwells

Key Components

Track Systems: U-shaped channels that secure the top and bottom of stud arrays:

  • Standard track (for basic applications)
  • Slotted track (allows for structural movement)
  • Deep leg track (for increased deflection capabilities)

Bridging & Bracing:

  • Cold-rolled channel (CRC) bracing
  • Flat strap bracing
  • Clip angles and connectors

Specialty Products:

  • Resilient channels (RC-1) for acoustic isolation
  • Furring channels for wall finishes
  • Hat channels for ceiling applications

Performance Specifications

  • Structural Capacity: Measured in pounds per linear foot (plf)
  • Fire Resistance: Non-combustible material with melting point >2,500°F
  • Gauge Standards: Thickness ranging from 12 gauge (0.105") to 25 gauge (0.018")
  • Coating Options:
  • G40/G60/G90 galvanized (for standard applications)
  • Galvanneal (for improved paint adhesion)
  • Aluminum-zinc alloy (for enhanced corrosion resistance)

2. Insulation Technologies

Insulation is critical for thermal efficiency, sound attenuation, and overall building performance. Modern insulation products are designed to address multiple performance criteria simultaneously.

Primary Insulation Types

Mineral Wool (Stone/Rock Wool):

  • R-value: 3.0-4.3 per inch
  • Fire resistance: Class A (non-combustible)
  • Acoustic properties: NRC 0.95-1.05
  • Applications: Fire barriers, acoustic control, thermal insulation
  • Notable products: Rockwool SAFE, Owens Corning Thermafiber

Fiberglass Batts and Boards:

  • R-value: 2.9-4.3 per inch
  • Fire resistance: Class A (non-combustible core)
  • Acoustic properties: NRC 0.90-1.00
  • Applications: Cost-effective thermal and acoustic control
  • Notable products: Owens Corning PINK, CertainTeed Sustainable Insulation

Spray Applied Insulation:

Closed Cell Foam:

  • R-value: 6.0-7.0 per inch
  • Air barrier properties: Excellent (< 0.001 L/s/m²)
  • Water resistance: Vapor impermeable (< 1 perm)

Open Cell Foam:

  • R-value: 3.5-3.7 per inch
  • Acoustic properties: Superior sound damping
  • Cost: 30-40% less than closed cell

Rigid Board Insulation:

Polyisocyanurate (Polyiso):

  • R-value: 5.6-6.5 per inch
  • Facers: Reflective aluminum, fiberglass mat, or kraft paper

Extruded Polystyrene (XPS):

  • R-value: 5.0 per inch
  • Moisture resistance: Excellent (0.1% water absorption)
  • Compressive strength: 15-100 psi options

Expanded Polystyrene (EPS):

  • R-value: 3.6-4.2 per inch
  • Cost-effectiveness: Best value per R-value dollar

Advanced Insulation Technologies

Vacuum Insulated Panels (VIPs):

  • R-value: 25-30 per inch
  • Thickness: Ultra-thin (0.5"-1.0")
  • Limitations: Cannot be cut or penetrated on-site

Aerogel Insulation:

  • R-value: 8.0-10.0 per inch
  • Applications: Thermal bridging, space-constrained retrofits
  • Notable products: Aspen Aerogels Spaceloft


3. Drywall & Gypsum Products

Gypsum board (drywall) provides the visible interior finish while contributing to fire resistance, acoustic performance, and durability of wall assemblies.

Standard Drywall Classifications

  • Regular (Type X):
  • Thickness: 5/8" standard for commercial applications
  • Fire rating: 1 hour when properly installed
  • Core: Enhanced with fiberglass reinforcement
  • Type C:
  • Enhanced fire performance over Type X
  • Contains additional glass fibers and vermiculite
  • Fire rating: Up to 2 hours in specific assemblies
  • Moisture-Resistant (MR/Green Board):
  • Water-resistant core and facers
  • Applications: Bathrooms, kitchens, high-humidity areas
  • Limitations: Not recommended for wet areas or as tile backer
  • Abuse-Resistant:
  • Engineered for high-traffic commercial spaces
  • Fiberglass mesh or special core formulations
  • Impact resistance: Rated using ASTM C1629 standards

Specialty Gypsum Products

  • Acoustically Enhanced:
  • Laminated with sound-damping polymers
  • STC rating improvement: +10-15 points over standard construction
  • Products: National Gypsum SoundBreak XP, CertainTeed SilentFX
  • Mold and Moisture Resistant:
  • Score of 10 (highest) on ASTM D3273 test
  • Specialized paper or paperless facings
  • Proprietary core treatments
  • Shaftliner:
  • 1" thick for cavity shaft wall construction
  • Beveled edges for installation in C-H studs
  • 2-4 hour fire ratings available
  • Ceiling Panels:
  • Specialized for horizontal applications
  • Sag-resistant formulations
  • Various acoustical patterns and performance ratings

Performance Characteristics

  • Fire Resistance: Measured in hours per ASTM E119
  • Sound Attenuation: STC (Sound Transmission Class) and CAC (Ceiling Attenuation Class)
  • Impact Resistance: Levels 1-3 according to ASTM C1629
  • Indoor Air Quality: GREENGUARD Gold certification, low VOC

4. Joint Treatment & Finishing

Joint treatment systems create a seamless appearance while maintaining structural integrity and fire resistance of the wall assembly.

Joint Tape Options

Paper Tape:

  • Traditional and versatile
  • Highest strength when properly embedded
  • Pre-creased for corner applications
  • Best practice for fire-rated assemblies

Self-Adhesive Mesh Tape:

  • Open fiberglass mesh structure
  • Embedded alkali-resistant adhesive
  • Best for repairs and small projects
  • Not recommended for fire-rated assemblies

Composite Tapes:

  • Paper-backed with fiberglass reinforcement
  • Combines strength of paper with mold resistance
  • Premium option for high-performance walls

Joint Compounds

Setting-Type Compounds:

  • Chemical hardening through crystallization
  • Set times: 20, 45, 90, 210 minutes
  • Higher strength than drying compounds
  • Lower shrinkage rates
  • Examples: Durabond, Easy Sand

Drying-Type Compounds:

  • Air-drying formulations

Classifications:

  • All-purpose: versatile for taping and finishing
  • Taping: higher adhesion for embedding tape
  • Topping: smoother finish with easy sanding
  • Lightweight: reduced shrinkage and easier sanding

Specialty Compounds:

  • Dust Control: Formulated to reduce airborne particles
  • Mold Resistant: Includes biocides and fungicides
  • Quick-Setting: Rapid chemical curing for same-day finishing

Application Systems

Level of Finish (GA-214 Standard):

  • Level 0: No treatment
  • Level 1: Tape embedded in joint compound
  • Level 2: Tape plus one coat over tape and fasteners
  • Level 3: Level 2 plus one additional coat
  • Level 4: Standard finish (three coats), suitable for flat paints
  • Level 5: Level 4 plus skim coat, required for glossy finishes or critical lighting

5. Firestop Systems

Firestop systems are engineered to maintain the fire-resistive integrity of walls by sealing penetrations, joints, and gaps that would otherwise allow fire and smoke to spread.

Types of Firestop Systems

Through-Penetration Firestops:

  • Seals openings where items pass through fire-rated walls
  • Common applications: pipes, conduits, cable trays, HVAC ducts

Products:

  • Intumescent sealants (expand when heated)
  • Firestop putty and putty pads
  • Firestop collars and wraps
  • Cast-in-place devices

Construction Joint Firestops:

  • Maintains fire resistance at joints between walls, floors, and ceilings
  • Applications: Head-of-wall, bottom-of-wall, perimeter joints

Products:

  • Spray-applied firestop materials
  • Firestop sealants
  • Compression seals
  • Pre-formed firestop devices

Perimeter Fire Barrier Systems:

  • Addresses the gap between exterior walls and floor assemblies
  • Critical for curtain wall construction

Components:

  • Mechanical attachment systems
  • Safing insulation
  • Smoke seals

Testing and Certification

ASTM Standards:

  • ASTM E814/UL 1479: Through-penetration firestop systems
  • ASTM E1966/UL 2079: Joint systems in fire-resistive constructions
  • ASTM E2307: Perimeter fire barriers

Fire Ratings:

  • F-Rating: Time period the system prevents flame passage
  • T-Rating: Time period the system limits temperature rise
  • L-Rating: Air leakage rating (smoke)
  • W-Rating: Water resistance

Documentation Requirements

  • UL System Numbers: Specific tested and listed assemblies
  • Engineering Judgments (EJs): For non-standard applications
  • Firestop Documentation: Required for building inspection and approval

6. System Integration & Performance

Wall systems achieve optimal performance when all components are selected, designed, and installed as an integrated assembly.

System Performance Categories

Structural Performance:

  • Wind load resistance (lateral forces)
  • Axial load capacity (vertical forces)
  • Deflection criteria (L/120, L/240, L/360)
  • Seismic considerations

Fire Performance:

  • Assembly fire ratings (1, 2, 3, 4 hour)
  • Surface burning characteristics (flame spread and smoke development)
  • Contribution to overall building compartmentation
  • Acoustic Performance:
  • Sound Transmission Class (STC): 35-60+ for walls
  • Impact Insulation Class (IIC): For floor-ceiling assemblies
  • Sound absorption coefficients for room acoustics
  • Thermal Performance:
  • Assembly U-values and R-values
  • Thermal bridging mitigation
  • Continuous insulation requirements

Specialized Wall Systems

  • Shaft Wall Systems:
  • 2-4 hour fire ratings
  • One-sided installation
  • Resilient to positive and negative air pressures

Area Separation Walls (Firewall):

  • 2-4 hour ratings between occupancy units
  • Structural independence
  • Break-away design for collapse protection

Security Walls:

  • Forced entry resistance
  • Ballistic ratings (UL 752 levels)
  • Detention grade construction

Healthcare Walls:

  • Infection control considerations
  • Impact and abuse resistance
  • Support for medical equipment and fixtures

7. Installation Best Practices

Proper installation techniques ensure that wall systems achieve their designed performance levels.

Metal Framing Installation

Layout and Placement:

  • Maximum spacing: 16" o.c. standard, 24" o.c. with engineering
  • Bracing requirements: Per structural calculations
  • Alignment tolerance: 1/8" in 10 feet

Connection Methods:

  • Screw types: #6, #8, #10, #12 based on gauge
  • Welding requirements: When specified by engineer
  • Powder-actuated fasteners: For concrete connections

Deflection Accommodation:

  • Slotted track installation
  • Deflection clips
  • Vertical slide connections

Insulation Installation

Cavity Insulation:

  • Full friction fit without compression
  • Split batting around bracing and services
  • Facing orientation and vapor barrier considerations

Continuous Insulation:

  • Minimize thermal bridges
  • Proper fastener selection and spacing
  • Air/weather barrier integration

Drywall Installation

Panel Orientation:

  • Horizontal vs. vertical installation
  • Joint staggering patterns
  • Fire-rated assembly requirements

Fastener Systems:

  • Screw types: Type S for steel framing
  • Spacing: 8" o.c. at edges, 12" o.c. in field
  • Edge distance: Minimum 3/8" from panel edges

Control Joints:

  • Maximum spacing: 30' for uninterrupted walls
  • Required at changes in framing direction
  • Required at wall/ceiling transitions

Firestop Installation

UL System Compliance:

  • Strict adherence to tested systems
  • Documentation of materials and methods
  • Field quality control testing

Inspection Requirements:

  • Visual inspection before concealment
  • Destructive testing when specified
  • Third-party verification for critical applications


8. Performance Testing & Certification

Wall systems undergo rigorous testing to verify performance claims and ensure code compliance.

Common Test Standards

  • ASTM E119: Fire Tests of Building Construction and Materials
  • ASTM E90: Laboratory Measurement of Airborne Sound Transmission
  • ASTM E72: Standard Test Methods of Conducting Strength Tests of Panels for Building Construction
  • ASTM E331: Water Penetration of Exterior Windows, Skylights, Doors, and Curtain Walls
  • ASTM C1629: Abuse Resistance of Gypsum Panel Products

Quality Assurance Programs

  • UL Follow-Up Services: Periodic inspections of labeled assemblies
  • Gypsum Association GA-600: Fire Resistance and Sound Control Design Manual
  • AISI Cold-Formed Steel Framing Design Guide: Engineering standards
  • AWCI Technical Manual 12-B: Industry standards for levels of finish

Documentation Requirements

  • Submittal Documentation: Product data, test reports, samples
  • Quality Control Reports: Inspection logs, material certifications
  • Close-out Documentation: As-built drawings, warranty information

Conclusion

The integration of metal framing, insulation, drywall, joint treatment, and firestop systems creates wall assemblies that meet modern performance requirements for safety, efficiency, and durability. Understanding the technical aspects of each component and how they work together enables designers, builders, and owners to create wall systems optimized for specific project needs.

By selecting appropriate components, following proper installation techniques, and adhering to testing and certification standards, walls can achieve the desired balance of structural integrity, fire resistance, acoustic control, thermal efficiency, and aesthetic quality